PPEEEERR RREEVVIIEEWW
The Malaysian Surveyor
about the functionality of some of show the museums’ commitment Kaplan, M. E., & Watts, J. M. (2001).
the ï¬re safety equipment. There was to ensuring minimum ï¬re safety Fire risk index for historic buildings.
no evidence that the installed ï¬re regulations are complied with and Fire Technology Journal, 37, 167-180.
extinguishers were checked, tested provides operational principles for
or serviced at least once a year. ï¬re safety. Perbadanan Muzium Melaka
2. Upgrade of ï¬re safety protection (PERZIM). (2013). Available at www.
7.0 Conclusion systems to meet building perzim.gov.my/
regulations such as UBBL
A ï¬re risk assessment was 1984, MS1183:2015 and FRDM Ramachandran, G., & Charters, D.
performed on three selected historic requirements. (2011). Quantitative risk assessment in
museums in Malacca designated 3. Good housekeeping for the ï¬re safety. Routledge.
as heritage buildings. Findings museums is needed for lowering
from the ï¬re safety audit showed the chance of ï¬re occurring Reyers, J. (2003). Risk and liability
that, ï¬re hazards were present in through proper monitoring for of consultants advising on built
all the observed buildings with poor combustible materials. heritage. Structural Survey, 21, 8-15.
housekeeping practices; escape 4. Regular inspection and
routes were insufï¬cient and some maintenance of installed ï¬re Bukowski, R. W. (1996). Fire Risk Or
hampered with consideration not safety systems by competent Fire Hazard as the Basis for Building
given to disabled people at two of the personnel. Fire Safety Performance Evaluation [Fire
observed museums; and ï¬re safety 5. Fire drills should be carried out Risk Or Fire Hazard-Building Fire Safety].
measures and protection systems regularly to train staffs and test National Institute of Standards and
installed were insufï¬cient with no work procedures appropriately. Technology.
evidence that provided ï¬reï¬ghting
equipment such as ï¬re extinguishers 8. Acknowledgement Salleh, N. H., & Ahmad, A. G. (2009).
were checked, tested or serviced Fire safety management in heritage
at least once a year resulting in This work was supported by the buildings: the current scenario in
non-compliance with ï¬re safety Ministry of Higher Education, Malaysia. 22nd CIPA Symposium,
provisions from UBBL 1984 and Fire Malaysia through the FRGS Grant October 11-15, Kyoto, Japan
and Rescue Department Malaysia. (Grant No.: FP046-2014B) which the
Following the ï¬re risk status of the authors are most thankful for. Watts, J. M. (2001). Fire protection
observed buildings, the following performance evaluation for historic
recommendations are made: References buildings. Journal of Fire Protection
Engineering, 11(4), 197-208.
1. Formulating a ï¬re safety policy Dawkin, A. (2001). Fire risk
as part of the health and safety management in heritage buildings.
policy. A ï¬re safety policy would Building Engineer, 76(7), 14-15.
38