Surveying the Condition of a Selected Flat Roof for Possible Water Ponding Defect
                                                                                                                                           Vol.50 No.2 2015

Figure 1: Flat roof layout plan and survey area

600 m2 of flat roof area consisting of 12      measured using a ruler. The findings were     a height of 30 mm to 35 mm. There was
points of rainwater downpipe (RWDP).           summarised according to the criticality of   also a watermark on the flat roof slab
The area involved in the survey is shown       each RWDP point, which was scored as         near this area at 30 mm. Dirt has been
in Figure 1.                                   low, medium, or high.                        identified on RWDPs 6 to 8, with the dirt
                                                                                            level reaching 35 mm to 40 mm. Figures
This survey was carried out using visual       4.0 Findings and                             8 to 10 show the respective conditions of
inspection. The overview and existing          Discussion                                   these flat roof areas.
condition of the survey area was recorded
using a camera. The survey area was            It was a sunny day when the survey was       The surface areas of the flat roof near
measured using a measuring tape and            conducted, although heavy rainfall was       RWDPs 9 to 12 do not show water
laser distance meter, and the number of        recorded 10 hours before the survey was      ponding. However, dirt and mold growth
RWDP was recorded. Figure 2 shows the          conducted. During the visual inspection,     has been identified in these areas. This
survey area and overview of the existing       water ponding and watermarks have            finding can be attributed to the stagnant
condition of the flat roof. The number of      been identified on several areas of the flat  water trapped at the surrounding RWDP
RWDP points is also labeled in Figure 2.       roof surface. Dirt has been identifiedon      points, which creates deposits of dirt. Dirt
                                               the gutters, and the dirt level reached      level in this area reached 25 mm to 35
General building inspection was carried        25 mm to 35 mm. However, there is no         mm. This area shows the water ponding
out to determine the existing condition of     water ponding on the surface area of the     effect, ecause the area is near the water
the flat roof and to identify any possibility  flat roof near RWDPs 1 to 5, as shown in     tank blocked by direct sunlight. Figures 11
of water ponding and watermark on              Figures 3 to 7, respectively.                to 14 show the respective conditions of
the flat roof surface. It also aimed to                                                     these flat roof areas.
determine the presence of dirt around          Water ponding has also been identified on
the cages of RWDPs, which might cause          the flat roof surface near RWDPs 6 and 8.    Based on the observations on the next
water ponding on the flat roof surfaces.       Water ponding level on this area reached     page, water ponding that occurs in this
The height of water ponding and dirt were                                                   flat roof area is caused by deposited

                                                                                            19